Skip to main content

ARIIDTM - A Research on Innovative Islanding Detection Technique for Microgrid - Research Thesis by Dr.V.Arivumani

  Abstract: 

Islanding detection is a way of protecting the renewable energy integrated Microgrid from the power grid network during abnormal conditions like hazards, faults, etc. Various islanding detection methods (Passive, Active, Hybrid and Remote methods) are implemented with new technologies to protect renewable energy-powered Microgrids integrated with the power grid network. However, among these methods, Passive methods are preferred and reported in most of the literature due to their known feasibility. These methods are straightforward to model with few processing elements, fewer computational requirements, and faster detection of islanding events without affecting the power quality. Yet, these methods have larger NonDetection Zone (NDZ) in which the islanding is not performed for minor power mismatches. Other than a voltage-frequency relay, most practices have less NDZ but more interrupted tripping, affecting the Microgrid's equipment. In this research, islanding detection is performed by sensing the voltage deviation (overvoltage and undervoltage) and voltage unbalance conditions using four proposed techniques. Angular symmetrical component (ASC) based islanding detection technique is performed using Delta Voltage Deviation (DVD) and Tangent Angle of Unbalance (TAU) parameters. Voltage and angle deviation (VAD) based islanding detection is performed by estimating absolute maximum deviation of voltage and phase angle from rated voltage and 1200 respectively. Voltage deviation and unbalance (VDU) based islanding detection is performed by estimating absolute maximum voltage deviation and voltage unbalance factor which is estimated from individual line voltage deviations. Finally, the islanding detection is simply performed using minimum and maximum line voltage (MMV) among three unequal line iv voltages in the unbalance conditions. The threshold setting of Voltage deviation is fixed as 10% as per IEC 62116. The threshold setting of tangent angle of unbalance, maximum phase angle deviation, voltage unbalance factor, and the % of minimum voltage with maximum voltage are set as 10 , 20 , 2% and 97% respectively. The proposed methods are validated in solar photovoltaic integrated Microgrid under various islanding and non-islanding events with the help of MATLAB/SIMULINK software. Performance of the proposed islanding detection methods are compared with the conventional methods available in the literature, such as Overvoltage / Undervoltage / Overfrequency / Underfrequency relay, Rate of Change of Frequency (ROCOF), and Voltage Unbalance and Total Harmonic Distortion (VUTHD) by simulation results. From the simulation results, it is evident that the proposed techniques effectively identify the islanding events under voltage deviation and unbalance conditions in microgrid. Also, the relays will not detect the islanding during internal events like linear and non-linear load switching. From the investigations made, it is found that Minimum and Maximum Voltage based islanding detection involves fewer computational requirements and hence it is found suitable for islanding detection in real time under any abnormal conditions.


 The Thesis is available in ShodhGanga: https://shodhganga.inflibnet.ac.in/jspui/handle/10603/564562


Citation Link: https://hdl.handle.net/10603/564562

Comments

Popular posts from this blog

Welcome to NQH by Dr.VAM!

NQH Logo Network of Quality Hosting (abbreviated as NQH) is created and maintained by Dr.VAM (Arivumani Velmurugan). This network provides various web services, small business sites, Social Blog of Fun posts, Tech updates and more... NQH is the brand created by registration of domain 'Nqh.in' with BigRock on 2.11.2025. Keep visiting NQH for more updates soon.

Top UPI Apps in Nov 2025

Top UPI Apps based on Transaction Volumes. Here are the UPI apps ranked by total transaction volume in October 2025: Rank UPI App Number of Transactions (Oct-2025) Share by Volume* 1 PhonePe ~ 9,412 million (~9.4 billion) ~ 45.47%  2 Google Pay ~ 7,166 million (~7.1 billion) ~ 34.62%  3 Paytm ~ 1,523 million (~1.52 billion) ~ 7.36%  4 Navi ~ 574.30 million ~ 2.77%  5 super.money (Flipkart) ~ 264.79 million ~ 1.28%  6 CRED ~ 157.99 million — (smaller share) 7 BHIM ~ 125.70 million < 1% 8 Amazon Pay ~ 94.32 million < 1% Here are the UPI apps ranked by transaction value in October 2025, based on NPCI / industry-reports: Rank UPI App Approx. Transaction Value (Oct 2025) Share of Total UPI Value 1 PhonePe ~ ₹ 13,06,401.90 crore ~ 47.88%  2 Google Pay ~ ₹ 9,54,186.10 crore ~ 34.98%  3 Paytm ~ ₹ 1,67,177.27 crore ~ 6.13%  4 CRED ~ ₹ 62,438.03 crore ~ 2.29%  5 Navi ~ ₹ 30,618 crore (≈ ₹ 306.18 billion) ~ 1.12% (derived from ...

தபோகம் - தமிழ்நாடு அரசு போக்குவரத்து கழகம் சுருக்க பெயர்கள்

தமிழ்நாடு அரசு போக்குவரத்து கழகம் 8 கோட்டங்களை கொண்டுள்ளது. அவற்றின் தமிழ் சுருக்க பெயர்கள் இங்கே தரப்பட்டுள்ளது. TNSTC - தநாஅபோக 1. MTC - மாபோகம் சென்னை  மாநகர் போக்குவரத்து கழகம் 2. TNSTC Villupuram - தபோகம் விழுப்புரம்  3. TNSTC Salem - தபோகம் சேலம்  4. TNSTC Kovai - தபோகம் கோவை  5. TNSTC கும்பகோணம் கே தபோகம் குடந்தை /கும்பகோணம் 6. TNSTC Madurai - தபோகம் மதுரை  7. TNSTC Tirunelveli - தபோகம் நெல்லை/திருநெல்வேலி 8. SETC - விபோகம் தமிழ்நாடு